Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2021  |  Volume : 17  |  Issue : 2  |  Page : 463-470

Dosimetric impact of dwell time deviation constraint on inverse brachytherapy treatment planning and comparison with conventional optimization method for interstitial brachytherapy implants


1 Department of Radiotherapy, Lok Nayak Hospital, Delhi; Research and Development Centre, Bharathiar University, Coimbatore, Tamil Nadu, India
2 Department of Radiotherapy, Dr. BRA IRCH, AIIMS, Delhi, India
3 Department of Radiotherapy, Lok Nayak Hospital, Delhi, India

Correspondence Address:
Saurabh Roy
Room No. 123, Department of Radiotherapy, Lok Nayak Hospital, Gate No. 2, Jawahar Lal Nehru Marg, Delhi - 110 002
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jcrt.JCRT_749_19

Rights and Permissions

Purpose: High-dose rate remote afterloading brachytherapy machine and advanced treatment planning system help in getting optimum dose to tumor and low dose to normal structures. Inverse planning simulated annealing (IPSA) optimization technique has a unique feature of dwell time deviation constraint (DTDC). In this study, six IPSA-based plans having different DTDC values with routinely practiced geometric plus graphical optimization (GO + GrO) have been compared using various dosimetric parameters. Materials and Methods: For this retrospective study, we have generated IPSA-optimized interstitial brachytherapy plans for ten cancer cervix patients. Routinely practiced GO + GrO-based plans were compared with six different IPSA plans having varying DTDC values from 0.0 to 1.0 using different dosimetric indices. Results: Conformity index and homogeneity index (HI) were higher in GO + GrO plans, compared to IPSA-optimized plans. However, HI of IPSA plans was increasing with increasing DTDC values. High-dose volumes were well controllable using DTDC parameter in IPSA-optimized plans. Dose to the rectum and bladder was smaller for IPSA-optimized plans than GO + GrO plans. Conclusions: One of the benefits of applying DTDC in IPSA-optimized plan is that it reduces high-dose volumes. Another advantage is the reduction in rectum and bladder dose.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed685    
    Printed17    
    Emailed0    
    PDF Downloaded34    
    Comments [Add]    

Recommend this journal