Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2020  |  Volume : 16  |  Issue : 8  |  Page : 53-58

Cytopathology-histopathology correlation and the effect of nodule diameter on diagnostic performance in patients undergoing thyroid fine-needle aspiration biopsy


1 Division of Endocrinology and Metabolism, School of Medicine, Akdeniz University, Antalya, Turkey
2 Division of Endocrinology and Metabolism, Yunusemre State Hospital, Eskisehir, Turkey
3 Department of Pathology, School of Medicine, Akdeniz University, Antalya, Turkey
4 Department of Surgery, School of Medicine, Akdeniz University, Antalya, Turkey

Correspondence Address:
Ramazan Sari
Division of Endocrinology and Metabolism, School of Medicine, Akdeniz University, TR-07070, Antalya
Turkey
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jcrt.JCRT_219_18

Rights and Permissions

Introduction: Although thyroid fine-needle aspiration biopsy (FNAB) is established to have a good overall sensitivity and specificity, various outcomes have been reported on its performance in large nodules. The aim of the study was to evaluate the diagnostic performance of FNAB and the effect of the nodule diameter on its diagnostic performance. Materials and Methods: The outcomes of a total of 7319 patients who underwent FNAB over the course of 5 years were analyzed retrospectively and 648 patients who had undergone post-FNAB thyroidectomy or lobectomy were included in the study. FNAB results were classified according to the Bethesda system. After evaluating the compatibility between cytology and pathology results, all-nodules and diameter-based (<4 cm and ≥4 cm) sensitivity, specificity, false positivity, false negativity, and accuracy rates of FNAB were calculated. Results: Sensitivity of FNAB was 85.4% for all nodules, 88.3% for nodules <4 cm, and 75.8% for nodules >4 cm (P < 0.001). Specificity was 58.4% for all nodules, 49.3% for nodules <4 cm, and 75.1% for nodules >4cm (P < 0.001). While false positivity was 41.6% for all nodules, it was 50.7% for nodules smaller than 4 cm and was 24.9% for nodules larger than 4 cm (P < 0.001). False negativity was 14.6% for all nodules and was 11.7% for nodules smaller than 4 cm and 24.2% for nodules larger than 4 cm (P < 0.001). Finally, among the entire set of nodules, the accuracy was 64.4%, which was 59.2% in nodules smaller than 4 cm, and 75.2% in nodules larger than 4 cm (P < 0.001). Conclusion: Despite a higher rate of false negativity, FNAB has higher specificity and accuracy in large nodules than those in the small nodules. Nodule diameter should not be used alone as a criterion to recommend thyroidectomy to the patient.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed629    
    Printed67    
    Emailed0    
    PDF Downloaded71    
    Comments [Add]    

Recommend this journal