ORIGINAL ARTICLE
Year : 2016  |  Volume : 12  |  Issue : 1  |  Page : 43-46

The clinical application of in-house double lower limb auxiliary device in treating pelvic tumors


1 Department of Radiation Oncology, The Central Hospital of Cangzhou, Hebei, Cangzhou 061000, China
2 Department of Radiation Oncology, Third Hospital of Hebei Medical University, Shijiazhuang 050051, China
3 Procure Proton Therapy Center, Oklahoma City, 73142, USA

Correspondence Address:
Prof. Zhai Fu-Shan
Department of Radiation Oncology, Third Hospital of Hebei Medical University, Shijiazhuang 050051
China
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0973-1482.151942

Rights and Permissions

Objective: Patient positioning accuracy is critical in radiotherapy. To improve the patient positioning accuracy, a double lower limb auxiliary device has been developed to fix pelvis patients to treatment couch. A clinical study for comparing new device to conventional devices has been performed. Materials and Methods: Thirty patients with pelvic tumor were randomly divided into conventional thermoplastic membrane fixation group (conventional fixing group) and conventional thermoplastic membrane plus lower limb auxiliary fixture group (auxiliary fixing group). The setup error was acquired by simulator position alignment with center field digital radiograph reconstruction (DRR) image from treatment planning system, The correlations between the conventional fixing group and the auxiliary fixing group were analyzed using Pearson's Chi-squared test. Results: Set-up errors in conventional fixing group and auxiliary fixing group were respectively 3.8 ± 1.5 mm and 1.4 ± 0.9 mm (P< 0.02), 5.4 ± 2.5 mm and 1.2 ± 1.2mm (P < 0.001), 2.2 ± 1.3 mm and 1.9 ± 1.0 mm (P < 0.05) in the bilateral, superior-inferior and anterior-posterior direction. Conclusion: The double lower limbs auxiliary device can reduce pelvic patient positioning errors. It is very helpful in improving the daily clinical setup accuracy.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2593    
    Printed65    
    Emailed0    
    PDF Downloaded129    
    Comments [Add]    

Recommend this journal