Journal of Cancer Research and Therapeutics

ORIGINAL ARTICLE
Year
: 2019  |  Volume : 15  |  Issue : 3  |  Page : 522--527

Dosimetric analysis and clinical outcomes of brachial plexus as an organ-at-risk in head-and-neck cancer patients treated with intensity-modulated radiotherapy


Bhanu B Prakash1, Prahlad H Yathiraj1, T Krishna Sharan1, Anshul Singh1, Anusha S Reddy1, Srinidhi G Chandraguthi2, Ramya Bala Subramanian2, Jyothi Nagesh2, Sarath S Nair2, Donald J Fernandes1, Vidyasagar S Mamidipudi1 
1 Department of Radiotherapy and Oncology, Kasturba Medical College, Manipal University, Manipal, Karnataka, India
2 Department of Medical Physics, Manipal University, Manipal, Karnataka, India

Correspondence Address:
Dr. Prahlad H Yathiraj
Department of Radiotherapy and Oncology, Kasturba Medical College, Manipal University, Karnataka
India

Objectives: To document the dose received by brachial plexus (BP) in patients treated with intensity-modulated radiotherapy (IMRT) for head-and-neck squamous cell carcinoma (HNSCC) and report the incidence of brachial plexopathy. Methods: Newly diagnosed patients of HNSCC treated with radical or adjuvant IMRT were included in this retrospective study. No dosimetric constraints were applied for BP maximum dose equivalent dose (EQD2 α/β = 3). Patients with minimum 6-month follow-up were included and patients with suspicion of plexopathy were evaluated further. Results: Sixty-seven patients were eligible and 127 BP were analyzed. The mean BP maximum dose (BPmax) was 62.4 Gy (+6.9), while mean BP volume was 28.1 cc (+4.1). Proportion of patients receiving BPmax >66 and >70 Gy were 34.7% and 14.2%. The mean BPmax for T4 tumors was significantly higher than T1 tumors (65 vs. 57.5 Gy, P = 0.005) but when adjusted for N-category, T-category was not independently significant in accounting for BPmax >66 or >70 Gy. Mean BPmax for N0 versus N2+ was 59.8 versus 65.6 Gy (P = 0.0001) and N1 versus N2+ was 61.6 versus 65.6 Gy (P = 0.018). After adjusting for T-category, patients with N2+ had a mean 4.2 Gy higher BPmax than N0-N1 (P = 0.0001). Stage III–IV patients had a mean six Gy higher BPmax doses than Stage I–II disease (P = 0.0001). With a median follow-up of 28 months (interquartile range 16–42), no patient had brachial plexopathy. Conclusion: Clinically significant plexopathy was not seen in spite of majority having over 2-years follow-up and a third of patients having dose above the recommended tolerance. Only nodal category independently influenced dose to the brachial plexii.


How to cite this article:
Prakash BB, Yathiraj PH, Sharan T K, Singh A, Reddy AS, Chandraguthi SG, Subramanian RB, Nagesh J, Nair SS, Fernandes DJ, Mamidipudi VS. Dosimetric analysis and clinical outcomes of brachial plexus as an organ-at-risk in head-and-neck cancer patients treated with intensity-modulated radiotherapy.J Can Res Ther 2019;15:522-527


How to cite this URL:
Prakash BB, Yathiraj PH, Sharan T K, Singh A, Reddy AS, Chandraguthi SG, Subramanian RB, Nagesh J, Nair SS, Fernandes DJ, Mamidipudi VS. Dosimetric analysis and clinical outcomes of brachial plexus as an organ-at-risk in head-and-neck cancer patients treated with intensity-modulated radiotherapy. J Can Res Ther [serial online] 2019 [cited 2020 Sep 30 ];15:522-527
Available from: http://www.cancerjournal.net/article.asp?issn=0973-1482;year=2019;volume=15;issue=3;spage=522;epage=527;aulast=Prakash;type=0