Journal of Cancer Research and Therapeutics

ORIGINAL ARTICLE
Year
: 2016  |  Volume : 12  |  Issue : 2  |  Page : 852--857

Dosimetric comparison of intensity modulated radiosurgery with dynamic conformal arc radiosurgery for small cranial lesions


Juan F Calvo-Ortega, David Delgado, Sandra Moragues, Miquel Pozo, Joan Casals 
 Department of Radiation Oncology, Hospital Quirón Barcelona, Barcelona, Spain

Correspondence Address:
Juan F Calvo-Ortega
Department of Radiation Oncology, Hospital Quiron Barcelona, Plaza Alfonso Comin, 5, 08023 Barcelona
Spain

Aims: To dosimetrically compare the fixed gantry intensity modulated radiosurgery (IMRS) with dynamic conformal arc radiosurgery (DCARS) for cranial lesions. This study investigates whether IMRS can be an adequate dosimetric alternative to DCARS for cranial stereotactic radiosurgery (SRS). Subjects and Methods: Forty-five SRS procedures for solitary brain metastasis (range: 0.44–29.18 cm 3) performed at our institution were selected for this study. Two plans were generated per patient: One IMRS plan using a multileaf collimation (MLC) of 5 mm, and one DCARS plan designed with a 3 mm micro-MLC. Dosimetric comparison metrics include the target coverage (Cov), conformity index (CI), homogeneity index (HI), gradient index (GI), and volume of the normal brain tissue receiving ≥12 Gy (V12). In addition, maximum doses to organs at risk (OAR) (brainstem, optic apparatus and cochlea) were compared for both techniques. Results: Compared to DCARS, IMRS improved mean CI (IMRS: 0.81 vs. DCARS: 0.63, P < 0.001), with no significant difference in target Cov (IMRS: 0.99 vs. DCARS: 0.99, P > 0.05), HI (IMRS: 1.22 vs. DCARS: 1.24, P > 0.05), GI (IMRS: 5.44 vs. DACRS: 5.44, P > 0.05). A weak significant difference in V12 (IMRS: 4.6 cm 3 vs. 5.2 cm 3, P = 0.033) was obtained. Subgroup analysis per target volume (small: <1 cm 3, intermediate: ≤1 cm 3 and <5 cm 3 and large: ≥5 cm 3) only revealed the statistically difference for CI metric (P < 0.001). No significant differences were found for maximum dose to the OAR. Conclusions: We have shown that IMRS provides the dosimetric advantages compared with DCARS. Based on the dosimetric findings in this study, fixed gantry IMRS technique can be adopted as a standard procedure for cranial SRS when micro-MLC technology is not available on the linear accelerator.


How to cite this article:
Calvo-Ortega JF, Delgado D, Moragues S, Pozo M, Casals J. Dosimetric comparison of intensity modulated radiosurgery with dynamic conformal arc radiosurgery for small cranial lesions.J Can Res Ther 2016;12:852-857


How to cite this URL:
Calvo-Ortega JF, Delgado D, Moragues S, Pozo M, Casals J. Dosimetric comparison of intensity modulated radiosurgery with dynamic conformal arc radiosurgery for small cranial lesions. J Can Res Ther [serial online] 2016 [cited 2020 Aug 13 ];12:852-857
Available from: http://www.cancerjournal.net/article.asp?issn=0973-1482;year=2016;volume=12;issue=2;spage=852;epage=857;aulast=Calvo-Ortega;type=0