Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
 
ORIGINAL ARTICLE
Ahead of Print

Study of the effects of dwell time deviation constraints on inverse planning simulated annealing optimized plans of intracavitary brachytherapy of cancer cervix


1 Department of Radiotherapy, Lok Nayak Hospital, New Delhi; Research and Development Centre, Bharathiar University, Coimbatore, Tamil Nadu, India
2 Department of Radiotherapy, Dr. B.R.A. IRCH, AIIMS, New Delhi, India
3 Department of Radiotherapy, Lok Nayak Hospital, New Delhi, India

Correspondence Address:
Saurabh Roy,
Department of Radiotherapy, Lok Nayak Hospital, Room No. 123, Gate No. 2, Jawaharlal Nehru Marg, New Delhi - 110 002
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None

DOI: 10.4103/jcrt.JCRT_246_18

Purpose: High Dose Rate (HDR) remote afterloading brachytherapy machine and advanced treatment planning system have made it possible to make variations in individual dwell times across a catheter according to tumour density and for sparing normal structures. New inverse planning technique such as Inverse Planning Simulated Annealing (IPSA) has also been introduced. But very few institutions are venturing towards volume based IPSA optimised intracavitary brachytherapy. This study focuses on dwell time deviation constraint (DTDC) feature of IPSA based optimization which restricts the large variation of dwell time across the catheter. Methods and Material: For this retrospective study we have generated IPSA optimised intracavitary brachytherapy plans for 20 cancer cervix applications. The initial DTDC value of each IPSA plan was kept 0.0. Later on gradual increment was made in DTDC values in step of 0.2. Plan modulation index (M) defined by Ryan L. Smith et al was used for characterising the variation of dwell time modulation with respect to gradual increase in DTDC parameter. Results: Plan modulation index gradually decreases with increasing value of DTDC from 0.0 to 1.0. There was the 83% decrease in M value from IPSA of DTDC 0.0 to fully constrained IPSA of DTDC1.0. There is reduction of 8.26% and 6.95% for D2cc values of rectum and bladder respectively for DTDC 1.0 compared to DTDC 0.0. Conclusions: One of the benefits of applying DTDC constrained in IPSA plan is that, it removes local hot spots. It's another advantage is the reduction in rectum and bladder dose.


Print this article
Search
 Back
 
  Search Pubmed for
 
    -  Roy S
    -  Subramani V
    -  Singh K
    -  Rathi AK
    -  Savita A
    -  Aditi A
 Citation Manager
 Article Access Statistics
 Reader Comments
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed267    
    PDF Downloaded6    

Recommend this journal