Aim: In the present study, surface doses within the target area and contralateral breast (CLB) received during conventional treatment of carcinoma breast are evaluate and compared for treatment on two different beam energies, i.e., Co-60 γ-ray and 6 MV X-ray beams with thermoluminescent dosimeter, LiF:Mg, Ti (TLD-100). Materials and Methods: The study includes a group of 23 patients comprising 11 patients treated with Co-60 γ-ray beam and 12 patients by 6 MV X-ray beam. Results and Discussion: The treatment using Co-60 γ-ray and 6 MV X-ray beams contributes an average percentage dose of 8.15% ± 0.56% and 4.73% ± 0.94%, respectively, to CLB in mastectomy patients. The contribution of tangential fields (mastectomy) to the CLB doses ranges between 12.71 and 16.40 cGy (5.45%–7.03%) for treatment with Co-60 γ-ray beam and 6.33–10.95 cGy (1.86–4.69%) for treatment with 6 MV X-ray beam. The supraclavicular field (SCF) contributes 1.45%–1.93% and 1.02%–1.43% for treatment with Co-60 γ-ray and 6 MV X-ray beams, respectively. The average surface dose (normalized with breast dose) 89.1% ± 8.5% for Co-60 beam in the SCF region differs significantly from the 60.2% ± 13.0% value for 6 MV X-ray beam. Conclusion: The CLB doses for mastectomy patients are higher for Co-60 beam as compared to 6 MV X-ray beam, and better dose homogeneity is achieved within the irradiated breast from 6 MV X-ray beam. The CLB doses are slightly higher for patients treated with breast conservative radiotherapy or lumpectomy. The average surface dose to SCF decreases by ~30% of treated breast dose for treatment with 6 MV X-ray beam.


Print this article
Search
 Back
 
  Search Pubmed for
 
    -  Singh R
    -  Oinam AS
    -  Trivedi G
    -  Kainth HS
    -  Shahi JS
    -  Singh B
    -  Kapoor R
 Citation Manager
 Article Access Statistics
 Reader Comments
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed465    
    PDF Downloaded16    

Recommend this journal