Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2019  |  Volume : 15  |  Issue : 7  |  Page : 1589-1596

Individualized and inverse optimized needle configuration for combined intracavitary-interstitial brachytherapy in locally advanced cervical cancer


1 School of Mechanical Engineering, Tianjin University, Tianjin, China
2 Department of Radiation Oncology, Tianjin Medical University Cancer Institute and Hospital, Tianjin, China

Correspondence Address:
Prof. Zhiyong Yang
School of Mechanical Engineering, Tianjin University, No. 135 Yaguan Road, Haihe Education Park, Tianjin 300350
China
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jcrt.JCRT_292_19

Rights and Permissions

Objectives: The aim of this study is to address the limitation of combined intracavitary-interstitial (IC/IS) brachytherapy (BT) in locally advanced cervical cancer using standardized applicators and to determine the optimal dose distribution in patients with challenging tumors, innovative methods of customizing and optimizing the IS needle configuration for combined IC/IS BT are proposed and investigated. Materials and Methods: A software module that could customize the IS needle configuration and subsequently generate the digital model of guiding template for three-dimensional printing was developed and integrated into our in-house treatment planning system for BT. The inverse optimization method based on the technique of mixed-integer linear programming was introduced to determine the needle tracks out of a candidate pool and dwell times at corresponding locations to best meet dose objectives. A treatment planning study was conducted to evaluate the feasibility and performance of the proposed methods. Results: The workflow for combined IC/IS BT with customized and inverse optimized IS needle configuration was presented. Dosimetric results of the treatment planning study showed that sufficient target coverage could be obtained with the customized IS needle configuration for challenging cases. The proposed dose-based optimization method for IS needle configuration was feasible and effective. Improved target coverage and organ-at-risk sparing were achieved using the inverse planning method. Conclusions: Using the proposed methods of customizing and optimizing the IS needle configuration, the limitation in the standardized design of combined IC/IS applicators can be addressed, and sufficient target coverage is obtained in cervical cancer patients with unfavorable tumor topography and/or extra lateral expansion.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed137    
    Printed0    
    Emailed0    
    PDF Downloaded3    
    Comments [Add]    

Recommend this journal