Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2019  |  Volume : 15  |  Issue : 5  |  Page : 1035-1041

A comparative study for surface dose evaluation in conventional treatment of carcinoma breast patients irradiated with Co-60 and 6 MV radiation beam


1 Department of Radiotherapy, PGIMER; Department of Physics, Panjab University, Chandigarh, India
2 Department of Radiotherapy, PGIMER, Chandigarh, India
3 Department of Physics, Panjab University, Chandigarh, India
4 Department of Nuclear Medicine, PGIMER, Chandigarh, India

Correspondence Address:
Rakesh Kapoor
Department of Radiotherapy, PGIMER, Chandigarh - 160 012
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jcrt.JCRT_789_17

Rights and Permissions

Aim: In the present study, surface doses within the target area and contralateral breast (CLB) received during conventional treatment of carcinoma breast are evaluate and compared for treatment on two different beam energies, i.e., Co-60 γ-ray and 6 MV X-ray beams with thermoluminescent dosimeter, LiF:Mg, Ti (TLD-100). Materials and Methods: The study includes a group of 23 patients comprising 11 patients treated with Co-60 γ-ray beam and 12 patients by 6 MV X-ray beam. Results and Discussion: The treatment using Co-60 γ-ray and 6 MV X-ray beams contributes an average percentage dose of 8.15% ± 0.56% and 4.73% ± 0.94%, respectively, to CLB in mastectomy patients. The contribution of tangential fields (mastectomy) to the CLB doses ranges between 12.71 and 16.40 cGy (5.45%–7.03%) for treatment with Co-60 γ-ray beam and 6.33–10.95 cGy (1.86–4.69%) for treatment with 6 MV X-ray beam. The supraclavicular field (SCF) contributes 1.45%–1.93% and 1.02%–1.43% for treatment with Co-60 γ-ray and 6 MV X-ray beams, respectively. The average surface dose (normalized with breast dose) 89.1% ± 8.5% for Co-60 beam in the SCF region differs significantly from the 60.2% ± 13.0% value for 6 MV X-ray beam. Conclusion: The CLB doses for mastectomy patients are higher for Co-60 beam as compared to 6 MV X-ray beam, and better dose homogeneity is achieved within the irradiated breast from 6 MV X-ray beam. The CLB doses are slightly higher for patients treated with breast conservative radiotherapy or lumpectomy. The average surface dose to SCF decreases by ~30% of treated breast dose for treatment with 6 MV X-ray beam.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed562    
    Printed23    
    Emailed0    
    PDF Downloaded20    
    Comments [Add]    

Recommend this journal