Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2019  |  Volume : 15  |  Issue : 4  |  Page : 793-800

Feasibility of three-dimensional-printed template-guided 125I seed brachytherapy and dosimetric evaluation in patients with malignant tumor


1 Department of Oncology, The Hebei General Hospital, Shijiazhuang, China
2 Department of Bioengineering, Imperial College London, South Kensington, London, United Kingdom
3 Department of Radiation Oncology, Shandong Cancer Hospital Affiliated to Shandong University, Jinan; Department of Radiation Oncology, Shandong Province Key Laboratory of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong Academy of Medical Sciences, Shandong, China

Correspondence Address:
Juan Wang
Department of Oncology, The Hebei General Hospital, Shijiazhuang
China
Man Hu
Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Jinan
China
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jcrt.JCRT_347_18

Rights and Permissions

Objective: The objective of the study is to test whether three-dimensional (3D)-printed template can be used reproducibly for guiding malignant tumors brachytherapy and study the dosimetric consistency and adequacy between pre- and post-plan. Materials and Methods: Between January and December 2016 in our hospital, a total of 14 patients underwent 3D-printed template-guided brachytherapy. All the patients were fixed into position using a vacuum cushion before undertaking a computed tomography (CT) scan. After the preplan was designed, the templates were printed. The tumors were punctured through predesigned needle holes. Following this, another CT scan was used to confirm the locations of needles, and then the 125 I radioactive seeds were implanted into the tumor according to the preplan. Postplan was performed after the operation. Data of the D90 (minimum absorbed dose of 90% target volume), V90 (90% prescription dose coverage volume percentage of target volume), V100, V150, and seed number pre- and post-operation were collected and compared. Results: The mean D90, V90, V100, V150, and seed number preoperation were 94.96 ± 16.43 Gy, 94.64% ± 1.43%, 91.21% ± 1.59%, 65.01% ± 5.78%, and 46.67 ± 21.87, respectively. The mean D90, V90, V100, V150, and seed number postoperation were 91.97 ± 17.54 Gy, 93.35% ± 2.45%, 89.35% ± 3.21%, 63.40% ± 6.36%, and 46.60 ± 22.85, respectively. No significant difference between pre- and post-operation was observed across the data (P >0.05). Conclusion: For immobilized malignant tumors, 3D-printed template can be used reproducibly. The dose parameters in preplan can be achieved easily and satisfactorily by 3D-printed template guided brachytherapy, and it may become an easily reproducible standardized procedure in the future.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed74    
    Printed0    
    Emailed0    
    PDF Downloaded10    
    Comments [Add]    

Recommend this journal