ORIGINAL ARTICLE
Year : 2019  |  Volume : 15  |  Issue : 1  |  Page : 216-222

Assessment of radiation leakage from treatment applicator of Siemens Primus Plus and Siemens Artiste linear accelerators


1 Department of Physics, Faculty of Sciences, Ferdowsi University of Mashhad, Mashhad, Iran
2 Department of Biomedical Engineering and Medical Physics, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
3 Department of Medical Physics, Reza Radiation Oncology Center, Mashhad, Iran

Correspondence Address:
Dr. Mahdi Ghorbani
Department of Biomedical Engineering and Medical Physics, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Velenjak, Tehran
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jcrt.JCRT_1096_16

Rights and Permissions

Aim: The purpose of this study is to measure radiation leakage of Siemens Primus Plus and Siemens Artiste linear accelerators in electron mode and to compare the leakage level with that recommended by the International Electrotechnical Commission (IEC) standard. Materials and Methods: In this assessment, Siemens Primus Plus linear accelerator with 10 cm × 10 cm, 15 cm × 15 cm, and 25 cm × 25 cm applicators was used. The radiation leakage in lateral and vertical directions was measured for Siemens Primus Plus and Siemens Artiste linear accelerators. Results: Data derived from radiation leakage measurement for Siemens Primus Plus and Siemens Artiste linear accelerators in lateral direction from the field edge and in vertical direction from the applicator were reported. The radiation leakage data were then compared with the IEC standard to evaluate in-air field leakage. Conclusion: Comparing the radiation leakage level from fields with the IEC standard for two applicators, the maximum that was occurred for 12 MeV electron beam and applicator size of 10 cm × 10 cm in Siemens Artiste linear accelerator was 2.3%, which is less than the IEC's recommended limit of 10%. It is concluded that the leakage amount is much less than the specified limit and that both of the linear accelerators have high level of safety. Considering the measurement stage, it also needs to be noted that the beam angle affected the radiation leakage level from field edge, and in 25° angle, it is higher than in 0° angle. Comparing radiation leakage from the right side of the field for the two linear accelerators, the amount of leakage for Siemens Primus Plus linear accelerator is more than Siemens Artiste linear accelerator.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed549    
    Printed10    
    Emailed0    
    PDF Downloaded18    
    Comments [Add]    

Recommend this journal