ORIGINAL ARTICLE
Year : 2017  |  Volume : 13  |  Issue : 6  |  Page : 1007-1014

Evaluation of dose calculation accuracy of various algorithms in lung equivalent inhomogeneity: Comparison of calculated data with Gafchromic film measured results


1 Department of Radiotherapy, King George Medical University UP, Lucknow, Uttart Pradesh, India
2 Department of Radiotherapy, Dr. Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttart Pradesh, India

Correspondence Address:
Mr. Teerth Raj Verma
Department of Radiotherapy, King George Medical University, Lucknow - 226 003, Uttar Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0973-1482.168992

Rights and Permissions

Aim: To evaluate dose calculation accuracy of various algorithms in lung equivalent inhomogeneity comprising tumor within it and comparison with Gafchromic film data. Materials and Methods: Gafchromic film measured central axis absorbed dose in lung insert (−700 Hounsfield unit [HU]), in racemosa wood cylindrical inhomogeneity (−725 HU) and at three surfaces of tumor (−20 HU) created in cylindrical inhomogeneity, put in the cavity of computerized imaging reference systems (CIRS) thorax phantom were compared with convolution (CON), superposition (SP), fast SP (FSP), and X-ray voxel Monte Carlo (XVMC) algorithms calculated dose using 6 MV beams of field size 2 cm × 2 cm, 3 cm × 3 cm, 4 cm × 4 cm, 5 cm × 5 cm, and 8 cm × 8 cm. Results: XVMC was in good agreement with film measured results for all selected field sizes except 3 cm × 3 cm. SP under estimated by 5.7% at the center of the lung insert while deviation up to 6% was found at the cent of wood inhomogeneity in 2 cm × 2 cm. Except CON, increase in dose from proximal to the central surface of the tumor and then dose falloff from central to the distal surface for field size 2 cm × 2 cm to 4 cm × 4 cm was recorded. The change in film measured percentage depth dose from 2 cm × 2 cm to 3 cm × 3 cm field sizes was found –8% however for consecutive field size(s) larger than 3 cm × 3 cm this difference was less. CON and FSP produced overestimated results. Conclusion: Out of four algorithms, XVMC found consistent with measured data. The electronic disequilibrium within and at the interface of inhomogeneity make the accurate dose predictions difficult. These limitations results in deviations from the expected results of the treatments.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1513    
    Printed104    
    Emailed0    
    PDF Downloaded128    
    Comments [Add]    

Recommend this journal