A study on the tumor volume computation between different 3D treatment planning systems in radiotherapy


Department of Radiation Oncology, Institute Rotary Cancer Hospital, All India Institute of Medical Sciences, New Delhi, India

Correspondence Address:
Ramachandran Prabhakar
Department of Radiation Oncology, Institute Rotary Cancer Hospital, All India Institute of Medical Sciences, New Delhi - 110 029
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0973-1482.82917

Rights and Permissions

Background: Tumor volume plays a crucial role in the survival and local control of the patients treated with radiotherapy. The dose volume histogram also depends on the accuracy of the tumor delineation. Aims: The main aim is to study the variation observed in the computation of the target volume with different treatment planning systems and treatment sites. Materials and Methods: Sixty patients of different treatment sites which include brain, retinoblastoma, head and neck, lung, gall bladder, liver, anal canal etc, were selected for this study. The tumor volume was delineated on the Eclipse treatment planning systems and CT datasets and DICOM-RT structure sets were transferred to Pinnacle, Oncentra, Plato, Precise, Ergo++, and Tomocon contouring workstations. The recomputed volume from these planning systems was compared with the reference volume obtained from Eclipse. Similarly, the accuracy in generating PTV from CTV was also assessed with different planning systems for 5 and 10 mm. Statistical Analysis Used: SPSS 10.0 was used for analysis. Results: The overall comparison of the volume with different planning systems showed that Pinnacle calculated relatively larger volume followed by Plato as compared to Eclipse, whereas TOMOCON, Ergo ++, and Oncentra showed reduced volume. As far as the variation in CTV to PTV volume is concerned, pinnacle showed a relatively higher volume as compared to the Eclipse planning systems. Conclusion: The study shows that all the treatment planning systems showed variation in computing the tumor volume and the CTV to PTV generation also varied with the planning systems.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed8216    
    Printed172    
    Emailed4    
    PDF Downloaded574    
    Comments [Add]    
    Cited by others 4    

Recommend this journal