Rights and Permissions

Aim : Compare the planning target volume (PTV) coverage in three different shielding techniques in cranial irradiation. Settings and Design : Tertiary care center, prospective study. Materials and Methods : The whole brain and meninges were contoured in ten planning CT scans, and expanded by 5 mm for the PTV. Shielding was designed using the French Society of Pediatric Oncology (SFOP) guidelines (SFOP plan), in-house recommendation (with 1 cm margin from the orbital roof and sphenoid wing) on a igitally Reconstructed Radiograph (DRR) and a third plan was generated using a 3D conformal radiation technique (3DCRT). The coverage of the PTV was noted using the isodose covering 95% of the PTV(D95), minimum dose within the PTV(D min ), and maximum dose within the PTV(D max ). The location of PTV not covered by the 95% isodose curve was noted. The median dose and maximum dose (D max ) to both eyes and maximum dose D max for the lens were noted. Statistical Analysis : General linear model method repeated the measure of analysis of variance test (ANOVA). Results : PTV coverage was significantly poorer in the SFOP and in-house plans as compared to 3DCRT plan (P=0.04). Median volume of PTV not covered by 95% isodose curve was 4.18 cc, 1.01 cc, and 0 cc in SFOP, in-house, and 3DCRT plan, respectively. Conclusions : In the absence of volumetric planning techniques, SFOP guidelines lead to inadequate coverage and the in-house method is recommended.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed6213    
    Printed153    
    Emailed1    
    PDF Downloaded353    
    Comments [Add]    
    Cited by others 1    

Recommend this journal