Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 


 
 Table of Contents  
INVITED EDITORIAL
Year : 2010  |  Volume : 6  |  Issue : 1  |  Page : 3-4

Evolution of radiation oncology: Sharp gun, but a blurred target


Department of Radiation Oncology, Tata Memorial Hospital, Mumbai, India

Date of Web Publication15-May-2010

Correspondence Address:
Anusheel Munshi
Assistant Professor, Radiation Oncology, 120, Tata Memorial Hospital, Parel, Mumbai-400 012
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0973-1482.63550

Rights and Permissions

How to cite this article:
Munshi A, Agarwal JP. Evolution of radiation oncology: Sharp gun, but a blurred target. J Can Res Ther 2010;6:3-4

How to cite this URL:
Munshi A, Agarwal JP. Evolution of radiation oncology: Sharp gun, but a blurred target. J Can Res Ther [serial online] 2010 [cited 2019 Sep 20];6:3-4. Available from: http://www.cancerjournal.net/text.asp?2010/6/1/3/63550

"In the long history of humankind (and animal kind, too) those who learned to collaborate and improvise most effectively have prevailed." …….…"It is not the strongest of the species that survives, nor the most intelligent that survives. It is the one that is the most adaptable to evolving change"…. Charles Darwin .

As per the legendary law of Charles Darwin, natural life, depending on the need of the species concerned, evolves in a stepwise and orderly fashion. [1] By and large, medicine is no exception to this general rule, with one milestone being the leading light for the next and higher frontier. Over the past two decades, Radiation Oncology too has taken huge technology strides. The traditional low energy orthovoltage machines have become a curiosity. Cobalt machines, which replaced the orthovoltage machines have bowed down to elegant and sophisticated linear accelerators (LA). Of late, LAs themselves have undergone radical (almost biannual!) transformation from machines capable of delivering simple square or rectangular 4 MV/6 MV beams to the current C arm LA which boasts of multileaf collimators, arc treatment, asymmetric jaws and dynamic motion capabilities. Taking a cue from computerized tomography (CT) scanners, helical rotational machines have mushroomed across the globe. [2] Intensity Modulated Radiotherapy and Image Guided Radiotherapy are the latest feathers in the cap for radiation delivery. These technologies allow us to create amazing patterns of dose fluence across the target area, allowing to deliberately inhomogenise the dose intensity depending on the risk of disease recurrence for a sub volume within the target area. In sum, modern radiation oncology set up is easily capable of precision delivery to a sub millimeter level. [3]

However, from an unbiased and neutral perspective, this rapid development of technology is intriguing. [4] This puzzle can be understood by revising the fundamentals of clinical practice in radiation oncology. In radiation oncology parlance, the gross tumor volume (GTV) denotes the gross visible or palpable tumor while the clinical target volume (CTV) determines the area of microscopic disease around the gross tumor. Finally, the planning target volume (PTV) indicates the extra margin to account for external set up and internal motion of the organs. Traditional radiotherapy essentially consisted of parallel pair or simple field arrangements with generous margins based on surface anatomy or fluoroscopic visualization. These liberal portals included both the disease site (GTV, CTV, PTV) while often including many areas of organs at risk (OAR) as well. True, in many instances this leads to considerable side effects and limited delivery of higher doses. Ostensibly, as a step forward, the present day radiotherapy planning involves CT slice based contouring of the tumor (GTV, CTV and PTV) and the OAR. [5] Efforts are being made to account for tumor motion and respiratory movement and many centers are already treating patients with elegant techniques of respiratory gating, breath control and so on.

However, in a rational order of evolution and development, precision delivery should have followed or paralleled the evolution of contouring. While newer imaging modalities in radiology have improved GTV imaging, serious issues regarding contouring of CTV and PTV remain. [6] In patients with an intact GTV a "suitable margin" is given by the radiation oncologist to account for microscopic spread of disease (or the CTV). Literature for the extent of this margin (derived from pathological series, imaging data, wisdom earned from pattern of recurrences) is limited for most sites. A patient who lands up after neoadjuvant chemotherapy or has been operated upon (thus distorting the muscle and the fat planes) is a perfect recipe for further and added uncertainty; especially after chemotherapy, the perineal dilemma is between hypothetically drawing the initial tumor from pre chemotherapy scans versus taking the post chemotherapy volume the target. Finally, the rules for giving the PTV margin (to account for internal motion and daily set up variations) are far from being ironed out. The proof of pudding for the aforesaid dilemma is the large interobserver variation seen for various studies involving contouring in recent studies. [7] Put simply, this leaves the radiation oncologist with a super sharp gun but a highly blurred target [Figure 1].

What follow is a peculiar situation which the radiation oncology community should be cognizant of - being less forgiving in view of precision delivery, modern radiotherapy is at a higher risk of erroneously (and precisely!) sparing the tumor or conversely irradiating the OARs in some cases. [8],[9] This is reflected in warning bells sounded by reports of periparotid recurrences (in an attempt to give tighter margins aiming to save the parotid) in head and neck cancer patients treated with intensity modulated radiotherapy. [10] Similar reports could soon emerge for other sites.

Historically, radiology and radiation oncology started as a single department and parted ways down the line. More and more of radiotherapy planning is, however, currently being done based on CT slices. Often these images are fused with magnetic resonance imaging (MRI), Positron emission tomography (PET) or perfusion images. It may be the perfect time for a partial reunion of sorts. In other words, time has come to stop working on perfecting the guns (at least for the time being!) and concentrate efforts on figuring out the target. Till then, the ghost of Darwin would continue to haunt us.

 
 > References Top

1.Ruse M. Charles Darwin on human evolution. J Econ Behav Organ 2009;71:10-9.   Back to cited text no. 1
    
2.Carol MP. Peacock TM. A system for planning and rotational delivery of intensity modulated fields. Int J Imag Sys Tech 1995;45:21-32.  Back to cited text no. 2
    
3.Vesper J, Bφlke B, Wille C, Gerber PA, Matuschek C, Peiper M, et al. Current concepts in stereotactic radiosurgery: A neurosurgical and radiooncological point of view. Eur J Med Res 2009;14:93-101.  Back to cited text no. 3
    
4.Glatstein E. Intensity-modulated radiation therapy: The inverse, the converse, and the perverse. Semin Radiat Oncol 2002;12:272-81.   Back to cited text no. 4
[PUBMED]  [FULLTEXT]  
5.Grιgoire V, Pφtter R, Wambersie A. General principles for prescribing, recording and reporting a therapeutic irradiation. Radiother Oncol 2004;73:S57-61  Back to cited text no. 5
    
6.Pirzkall A, McKnight TR, Graves EE, Carol MP, Sneed PK, Wara WW, et al. MR-spectroscopy guided target delineation for high-grade gliomas. Int J Radiat Oncol Biol Phys 2001;50:915-28.  Back to cited text no. 6
[PUBMED]  [FULLTEXT]  
7.Pena PC, Kirova YM, Campana F, Dendale R, Bollet MA, Fournier-Bidoz N, et al. Anatomical, clinical and radiological delineation of target volumes in breast cancer radiotherapy planning: Individual variability, questions and answers. Br J Radiol 2009;82:595-9.  Back to cited text no. 7
    
8.de Crevoisier R, Tucker SL, Dong L, Mohan R, Cheung R, Cox JD, et al. Increased risk of biochemical and local failure in patients with distended rectum on the planning CT for prostate cancer radiotherapy. Int J Radiat Oncol Biol Phys 2005;62:965-73.   Back to cited text no. 8
[PUBMED]  [FULLTEXT]  
9.Marks LB, Ma J. Challenges in the clinical application of advanced technologies to reduce radiation- associated normal tissue injury. Int J Radiat Oncol Biol Phys 2007;69:4-12.   Back to cited text no. 9
[PUBMED]    
10.Cannon DM, Lee NY. Recurrence in region of spared parotid gland after definitive intensity-modulated radiotherapy for head and neck cancer. Int J Radiat Oncol Biol Phys 2008;70:660-5.  Back to cited text no. 10
[PUBMED]  [FULLTEXT]  


    Figures

  [Figure 1]


This article has been cited by
1 Targeted therapy in cancer care A critical snapshot
Anusheel Munshi
Acta Oncologica. 2012; 51(1): 141
[Pubmed] | [DOI]
2 Targeted therapy in cancer care A critical snapshot
Munshi, A.
Acta Oncologica. 2012; 51(1): 141-142
[Pubmed]
3 Pitfalls of tungsten multileaf collimator in proton beam therapy
Moskvin, V., Cheng, C.-W., Das, I.J.
Medical Physics. 2011; 38(12): 6395-6406
[Pubmed]
4 Resurecting brachytherapy from brink of oblivion
Munshi, A.
Journal of Cancer Research and Therapeutics. 2011; 7(4): 391-392
[Pubmed]
5 Pitfalls of tungsten multileaf collimator in proton beam therapy
Vadim Moskvin,Chee-Wai Cheng,Indra J. Das
Medical Physics. 2011; 38(12): 6395
[Pubmed] | [DOI]
6 PENELOPE Monte Carlo engine for treatment planning in radiation therapy with very high energy electrons (VHEE) of 150-250 MeV
Moskvin, V., Salvat, F., Stewart, D.K., Desrosiers, C.M.
IEEE Nuclear Science Symposium Conference Record ,. 2010; art(5874117,): 1961-1966
[Pubmed]



 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

  >Article Figures
  In this article
>References

 Article Access Statistics
    Viewed2186    
    Printed190    
    Emailed0    
    PDF Downloaded323    
    Comments [Add]    
    Cited by others 6    

Recommend this journal


[TAG2]
[TAG3]
[TAG4]